Foundations and Foundation Walls: For All Classes of Buildings, Pile Driving, Building Stones and Bricks, Pier and Wall Construction, Mortars, Limes, Cements, Concretes, Stuccos, Etc. 60 Illustrations ...Bicknell & Comstock, 1879 - 119 pages |
Common terms and phrases
anchors Architecture ashlar asphalt asphaltum average barrels basalt base stones beams brickwork broken stone builder building built bushels cement mortar chimney clay coat color columns concrete construction cubic foot dampness diameter dimension stone driving earth eight inches ENAMEL PAINT erected excavation feet high feet in height feet long feet square feldspar five feet floor footing courses foundation walls four inches front girders granite gravel ground hammer hardpan headers hornblende Hydraulic Lime ILLUSTRATION inches in thickness inches thick inches inverted arches iron isolated piers joints laid load magnesia masonry method of isolated mortar North River one-quarter party walls pavements piles plaster of paris Portland cement pounds per square quarries rock Rosendale rubble sand silicate six inches sixteen inches slacked soil square foot square inch stories street structure stucco surface thick inches thick Tiel timber tons vaults York
Popular passages
Page 60 - Buildings, may bring and maintain an action against the person or persons last herein referred to, to recover the value of the work done and materials furnished in and about the said premises in the same manner as if he had been employed to do the said work by the said person or persons.
Page 61 - Portland cement concrete, they shall be at least eight inches thicker than the wall next above them to a depth of twelve feet below the curb level ; and for every additional ten feet, or part thereof, deeper, they shall be increased four inches in thickness. If built of brick, they shall be at least four inches thicker than the wall...
Page 64 - ... brick, and putting in diagonal headers behind the same, or by splitting face brick in half, and backing the same by a continuous row of headers. In all walls which are faced with thin ashlar, anchored to the backing, or in which the ashlar has not either alternate headers and stretchers in each course, or...
Page 65 - No swelled or refuse brick shall be allowed in any wall or pier ; and all brick used in the construction, alteration, or repair of any building, or part thereof, shall be good, hard, well-burnt brick.
Page 66 - In no case shall any wall or walls of any building be carried up more than two stories in advance of any other wall, except by permission of the Commissioner of Buildings having jurisdiction, but this prohibition shall not include the inclosure walls for skeleton buildings.
Page 66 - The ends of wood beams resting upon girders shall be butted together end to end and strapped by wrought-iron straps of the same size and distance apart, and in the same beam as the wall anchors, and shall be fastened in the same manner as said wall anchors.
Page 63 - Every temporary support placed under any structure, wall, girder, or beam, during the erection, finishing, alteration, or repairing of any building, or part thereof, shall be equal in strength to the permanent support required for such structure, wall, girder, or beam. And the walls of every building shall be strongly braced from the beams of each story until the building is...
Page 60 - ... not be less than two by three feet, and at least eight inches in thickness for walls; and not less than ten inches in thickness If under piers, columns or posts...
Page 63 - ... shall be securely braced during construction, both inside and out, if practicable ; or if outside bracing is not practicable, it shall be properly braced from the inside, and the braces shall be continued from the foundation upward to at least one-third the height of the building from the sidewalk level.
Page 64 - In all brick walls every sixth course shall be a heading course, except where walls are faced with brick in running bond, in which latter case every sixth course shall be bonded into the backing by cutting the course of the face brick and putting in diagonal headers behind the same, or by splitting the face brick in half and backing the same with a continuous row of headers.